PMT Separated Detector, PMT gabungan Scintillator Detector
Pambuka produk
Kinheng bisa nyedhiyakake detektor scintillator adhedhasar PMT, SiPM, PD kanggo spektrometer radiasi, dosimeter pribadi, pencitraan keamanan lan lapangan liyane.
1. Detektor seri SD
2. detektor seri ID
3. Detektor sinar-X energi kurang
4. Detektor seri SiPM
5. Detektor seri PD
Produk | |||||
Seri | Model No. | Katrangan | Input | Output | Konektor |
PS | PS-1 | Modul elektronik karo soket, 1 "PMT | 14 Pin |
|
|
PS-2 | Modul elektronik kanthi soket & sumber daya dhuwur / kurang-2 "PMT | 14 Pin |
|
| |
SD | SD-1 | Detektor.Integrasi 1” NaI(Tl) lan 1”PMT kanggo sinar Gamma |
| 14 Pin |
|
SD-2 | Detektor.Integrasi 2" NaI(Tl) lan 2"PMT kanggo sinar Gamma |
| 14 Pin |
| |
SD-2L | Detektor.Integrasi 2L NaI(Tl) lan 3”PMT kanggo sinar Gamma |
| 14 Pin |
| |
SD-4L | Detektor.Integrasi 4L NaI(Tl) lan 3”PMT kanggo sinar Gamma |
| 14 Pin |
| |
ID | ID-1 | Detektor Terpadu, kanthi 1” NaI(Tl), PMT, modul elektronik kanggo sinar Gamma. |
|
| GX16 |
ID-2 | Detektor Terintegrasi, kanthi 2" NaI(Tl), PMT, modul elektronik kanggo sinar Gamma. |
|
| GX16 | |
ID-2L | Detektor Terpadu, kanthi 2L NaI(Tl), PMT, modul elektronik kanggo sinar Gamma. |
|
| GX16 | |
ID-4L | Integrated Detector, karo 4L NaI(Tl), PMT, modul elektronik kanggo sinar Gamma. |
|
| GX16 | |
MCA | MCA-1024 | MCA, USB tipe-1024 Channel | 14 Pin |
|
|
MCA-2048 | MCA, USB tipe-2048 Channel | 14 Pin |
|
| |
MCA-X | MCA, GX16 jinis Konektor-1024~32768 saluran kasedhiya | 14 Pin |
|
| |
HV | H-1 | Modul HV |
|
|
|
HA-1 | Modul HV Luwes |
|
|
| |
HL-1 | Tegangan Dhuwur / Kurang |
|
|
| |
HLA-1 | Tegangan Luwes Dhuwur / Kurang |
|
|
| |
X | X-1 | Integrated detector-X ray 1" Crystal |
|
| GX16 |
S | S-1 | Detektor Terpadu SIPM |
|
| GX16 |
S-2 | Detektor Terpadu SIPM |
|
| GX16 |
Detektor seri SD ngemot kristal lan PMT dadi siji omah, sing ngatasi kerugian higroskopis sawetara kristal kalebu NaI(Tl), LaBr3:Ce, CLYC.Nalika kemasan PMT, bahan pelindung geomagnetik internal nyuda pengaruh medan geomagnetik ing detektor.Ditrapake kanggo ngitung pulsa, pangukuran spektrum energi lan pangukuran dosis radiasi.
Modul Soket PS-Plug |
SD- Detektor Dipisahake |
ID-Integrasi Detektor |
H- Tegangan dhuwur |
HL- Telpon Dhuwur / Low Voltage |
AH- Tegangan Dhuwur sing bisa diatur |
AHL- Luwes Dhuwur / Low Voltage |
MCA-Multi Channel Analyzer |
Detektor X-ray |
Detektor S-SiPM |
2" Probe Dimensi
Definisi Pin
Properti
ModelProperti | SD-1 | SD-2 | SD-2L | SD-4L |
Ukuran Kristal | 1” | 2"&3" | 50x100x400mm/100x100x200mm | 100x100x400mm |
PMT | CR125 | CR105, CR119 | CR119 | CR119 |
Suhu panyimpenan | -20 ~ 70 ℃ | -20 ~ 70 ℃ | -20 ~ 70 ℃ | -20 ~ 70 ℃ |
Suhu Operasi | 0~40 ℃ | 0~40 ℃ | 0~40 ℃ | 0~40 ℃ |
HV | 0~+1500V | 0~+1500V | 0~+1500V | 0~+1500V |
Scintillator | NaI(Tl), LaBr3, CeBr3 | NaI(Tl), LaBr3, CeBr3 | NaI(Tl), LaBr3, CeBr3 | NaI(Tl), LaBr3, CeBr3 |
Kelembapan Operasi | ≤70% | ≤70% | ≤70% | ≤70% |
Resolusi Energi | 6% ~ 8% | 6% ~ 8% | 7% ~ 8,5% | 7% ~ 8,5% |
Aplikasi
1. Pangukuran dosis radiasi
Dosis medisradiasiora kaya dosis obat.Nalika nerangake dosis radiasi, ana macem-macem jinis lan unit pangukuran.Dosis radiasi minangka topik sing rumit.
2. Pangukuran energi
Energi listrik minangka produk sakadaya listriklan wektu, lan diukur ing joule.Iki ditetepake minangka "1 joule energi padha karo 1 watt daya dikonsumsi kanggo 1 detik''.
IE Energi lan daya ana hubungane.Energi listrik bisa diukur mung nalikadaya listrikdikenal.Dadi pisanan, kita ngerti daya listrik
3. Analisis spektrum
Analisis spektrum utawa analisis spektrum yaiku analisis saka segi spektrum frekuensi utawa jumlah sing gegandhengan kayata energi, nilai eigen, lan liya-liyane. interaksi.
4. Identifikasi nuklida
Karakteristik radionuklida kasebut yaiku aktivitas, daya termal, tingkat produksi neutron, lan tingkat pelepasan foton.